Circuit Breaker Lockout, Breaker Lockout Device

Circuit breaker lockout is mainly used to prevent the sudden start of electrical equipment during maintenance and protection of personal safety. Our breaker lockout device isolate and secure almost any breaker switch. Provides snap-in and clamp options covering most circuit breakers. Oversize clamps and universal multipole breaker lockout devices are also available. It should be noted that the circuit breaker lockout only plays an isolation role. To lock the circuit breaker and mark the isolation state, it must be used in conjunction with safety padlock and lockout tag of the LEDS.
  • Circuit Breaker Switch Lock

    Circuit Breaker Switch Lock

    Materials: reinforced nylon, suitable for all types of circuit breakers, including ISO/DIN miniature circuit breaker locks, small, medium and large molded case circuit breakers, models complete...

  • 277 Volt Clamp-On Circuit Breaker Lockout

    277 Volt Clamp-On Circuit Breaker Lockout

    Model no. : LDC31, suitable for small and medium-sized molded case circuit breakers with a thickness of 13mm x 18m wide for switch handles. Material: reinforced nylon...

  • Grip Tight Circuit Breaker Lockout

    Grip Tight Circuit Breaker Lockout

    Model: LDC51, made of powder coated steel and reinforced polymer, can lock standard height and connecting rod circuit breaker, keyhole diameter 10mm, can be easily locked without any other tools....

  • No Tool Universal Circuit Breaker Lockout

    No Tool Universal Circuit Breaker Lockout

    Model: LDC24, made of reinforced nylon and copper structure, moulded case circuit breaker with handle thickness ≤10mm, keyhole diameter 10mm, can be easily locked without any other tools....

  • MCB Lockout Device

    MCB Lockout Device

    Model: LDC22, reinforced nylon lock body, locking handle thickness ≤8mm, suitable for single-pole/multi-pole miniature circuit breaker and small and medium-sized molded case circuit breaker, padlock diameter ≤8mm...

  • Miniature Circuit Breaker Lockout Pin Out Standard

    Miniature Circuit Breaker Lockout Pin Out Standard

    Model: LDC12, suitable for single/multipole miniature circuit breaker, hole distance ≤12mm, reinforced nylon lock body, dimension: 43mm H x 24mm W x 18mm D, can be installed without tools...

  • LOTO For MCB

    LOTO For MCB

    Model: LDC16, reinforced nylon lock body, locking handle thickness ≤7.7mm, suitable for single-pole/multi-pole miniature ISO/DIN circuit breakers, padlock diameter ≤7mm...

  • Red Breaker Lock

    Red Breaker Lock

    Material: reinforced nylon, model complete, suitable for all types DZ47 circuit breakers, including ISO/DIN miniature circuit breaker locks, class 1 (1P) and class 2 (2P) above...

  • Breaker Handle Lock

    Breaker Handle Lock

    Model: LDC21, reinforced nylon lock body, locking handle thickness ≤8mm, suitable for single-pole/multi-pole miniature circuit breaker and small and medium-sized molded case circuit breaker, padlock diameter ≤8mm...

  • Universal Circuit Breaker Lockout

    Universal Circuit Breaker Lockout

    Reinforced nylon + copper structure, locking handle thickness ≤8mm, suitable for single-pole/multi-pole miniature circuit breaker and small and medium-sized plastic case circuit breaker, padlock diameter ≤8mm...

  • Schneider Circuit Breaker Lockout

    Schneider Circuit Breaker Lockout

    Model: LDC72, suitable for single/multipole miniature circuit breaker, reinforced nylon lock body, dimension: 27mm H x 17.5mm W x 12mm D, can be installed without tools...

  • Electrical Breaker Lockout Device

    Electrical Breaker Lockout Device

    Materials: reinforced nylon, suitable for all types of circuit breakers, including ISO/DIN miniature circuit breaker locks, small, medium and large molded case circuit breakers, models complete...

Breaker Lockout Device Feature

1. Complete circuit breaker lockout manufacturer: provide the best safety for all workplaces requiring circuit breaker locking.
2. Minimal "toolless" option: Allows breaker lockout device to be locked in the off position without the use of tools, providing fast and easy installation.
3. Industry-leading clamping force: Prevents re-opening of the circuit breaker for maintenance or service safety.
4. General design: equipped with single-pole and multi-pole circuit breakers, most of the circuit breakers in the equipment can be locked effectively.
5. Rugged reinforced nylon and stainless steel/copper structure: provides strength, durability, added safety and corrosion resistance; Ideal for industrial and harsh environment applications.
6. Compact and light: convenient, easy to carry and store in a small lock bag.

Circuit Breaker Lockout Usage And Lockout Program

1. Get ready to shut down
Determine the type and intensity of the hazardous energy to be controlled and lock all isolation points and energy isolation devices; Obtain safety padlocks, lockout tags, breaker lockout device and other equipment necessary to complete the work.
2. Turn off the device
Notify all affected employees to shut down and shut down equipment in accordance with normal shutdown procedures. (e.g. On/off or start/stop buttons or switches).
3. Isolation
Operate circuit breaker lockout to isolate the machine or equipment from energy. This usually involves opening an open switch, circuit breaker, or valve in a closed state; Caution: Do not turn on the off switch without turning off the device, as it may cause an arc or explosion.
4. Use lockout/tagout devices
Safety padlocks and lockout tags on each energy isolation device to ensure that it is closed; When the energy isolation device requires a locking device, install the breaker lockout device, safety padlock, and signage to ensure that it is in the "off" state.
5. Blackout: Release or suppression of stored energy
After the use of the locking device, all stored or residual energy must be released, disconnected, restricted or otherwise made safe.
6. Verify
Before starting any work, verify that the machine or device is isolated and cannot be activated or restarted by manually operating the control button or switch to start or operate the machine or device and return control to their closed or neutral position.
7. Unlock